Elevator Interlock Function - Panasonic VG-M186D Operation Manual

Color monitor indoor master for digital pair wiring system
Table of Contents

Advertisement

Elevator Interlock Function

If the elevator is operating in security mode, the security functions can be momentarily disabled by
unlocking the lobby's electric lock and verifying the ID of the tenant.
Security Operation
If a suspicious person enters at the same time as a tenant or a visitor, you can prevent them from moving around
the building by restricting access to the elevator and at the floor they can get off. Contact the elevator
manufacturer for how to use security operation.
When the elevator is operating in security mode, someone will not be able to call the elevator or open the
elevator door if you do not unlock the door from the Indoor Master.
This procedure is not possible if the Apartment Building HA System is not linked to the elevator system.
Note
If you do not know what equipment is installed, contact the administrating company or manager's room.
Lobby Intercom
with Camera
異  常 次表示
宅  配 メッセージ
警戒中
施  錠
使用中 解  錠
電源
1
2
3
Keypad Buttons
4
5
6
7
8
9
0
呼出
Call
Indoor Master
Lobby 1
Receiver volume
REC
Full
Low High
Unl o ck
試験
VG-M186D
火災
電源
FIRE
WINDOW
POWER
押す
玄関
外出
PUSH
DOOR
ABSENT
警報音停止 画面表示
非 常
STOPALRM DISPLAY
EMERG.
ハンズフリー
HANDS FREE
30
1
The visitor calls the unit they want to visit
from the Lobby Intercom.
(Refer to page 25.)
2
You respond to the call and unlock the
lobby's electric lock.
3
The elevator is called to the lobby floor
when the lobby's electric lock is unlocked.
The visitor presses the button for the floor
where they want to get off.
* The visitor will not be able to call the elevator
or open the elevator door if you do not unlock
the door from the Indoor Master.
Fires
(Fire Alarm)
* Depending on the type of apartment building, either the Automatic Residential Fire Alarm or Automatic
Apartment Building Fire Alarm is used.
Automatic Residential Fire Alarm
If the detector is activated...
Monitor: Fire indicator flashes and
Indoor Master
    fire alarm is displayed.
Hardware: Fire indicator flashes and
  
VG-M186D
火災
電源
FIRE
WINDOW
POWER
押す
玄関
外出
Detector
PUSH
DOOR
ABSENT
警報音停止 画面表示
非 常
STOPALRM DISPLAY
Pin-pon pin-pon pin-pon. Warning, fire,
EMERG.
fire. A fire has broken out. Please
ハンズフリー
evacuate the premises in a safe manner.
HANDS FREE
(Byuu-byuu-byuu, 3 times)
Extension
VG-R397N
非常押ボタン
強く
押す
Pin-pon pin-pon pin-pon. Warning, fire,
fire. A fire has broken out. Please
evacuate the premises in a safe manner.
共同玄関
電 気 錠
室 内 呼
(Byuu-byuu-byuu, 3 times)
管理人呼
Expansion
Speaker
Pin-pon pin-pon pin-pon. Warning, fire,
fire. A fire has broken out. Please
evacuate the premises in a safe manner.
(Byuu-byuu-byuu, 3 times)
Alarm indicator flashes.
Pin-pon pin-pon pin-pon. Warning, fire,
fire. A fire has broken out. Please
Door Intercom
evacuate the premises in a safe manner.
(with alarm display and
(Byuu-byuu-byuu, 3 times)
remote test terminal)
or Color Camera Foyer Unit
■Resetting Detector
...The alarm will stop, and the display and fire indicator on the monitor and the alarm indicators on the Door Intercom (with
alarm display and remote test terminal) or Color Camera Foyer Unit will turn OFF. (Automatic Residential Fire Alarm)
...When the Alarm Stop Button is pressed and the alarm is stopped, the display and the fire indicator on the monitor, and the alarm
indicators on the Door Intercom (with alarm display and remote test terminal) or Color Camera Foyer Slave Unit will turn OFF.
(Automatic Apartment Building Fire Alarm)
■Example Cause of a False Alarm
...A false alarm will occur if a heater is used directly under a detector.
Notice
The fire alarm consists of a voice message that is repeated twice and then an alarm sound (byuu-byuu-byuu)
that is repeated three times.
Automatic Apartment Building Fire Alarm
After the specified time (2 to 5 minutes) after the detector is
activated or when the Fire Confirmation Button is pressed...
Response
Investigate the cause and
alarm stop indicator flashes.
respond immediately.
Stopping the Alarm
Press the Stop Alarm Button.
The stop alarm indicator will
turn OFF.
The fire indicator will
continue to flash.
火災
電源
FIRE
WINDOW
POWER
押す
玄関
外出
PUSH
DOOR
ABSENT
警報音停止 画面表示
非 常
STOPALRM DISPLAY
EMERG.
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vg-m187d

Table of Contents