Water Leaks (Water Leak Alarm); Emergencies (Emergency Alarm) - Panasonic VG-M186D Operation Manual

Color monitor indoor master for digital pair wiring system
Table of Contents

Advertisement

Water Leaks
(Water Leak Alarm)
■Water Leak Sensors Activated in the
 Bath or Kitchen
Monitor: The alert indicator flashes and
    the water leak alarm is displayed.
Indoor Master
Hardware: Stop Alarm Indicator flashes.
VG-M186D
火災
電源
FIRE
WINDOW
POWER
押す
玄関
外出
Water Leak
PUSH
DOOR
ABSENT
警報音停止 画面表示
非 常
Piko, piko.
Sensor
STOPALRM DISPLAY
EMERG.
Water leak
ハンズフリー
HANDS FREE
Extension
VG-R397N
非常押ボタン
強く
押す
Note
In some cases, only a
Piko, piko.
display appears and
Water leak
共同玄関
電 気 錠
there is no sound due to
室 内 呼
管理人呼
the settings made from
the Central Controller.
Expansion Speaker
Piko, piko.
Water leak
No alarm sound
Door Intercom
(with alarm display and
remote test terminal)
or Color Camera Foyer Unit
Notice
The alarm for a water leak automatically stops after 30 seconds. (The display for the water leak will not
disappear until the water leak stops.)
44
Response
Investigate the cause and
respond immediately.
Stopping the Alarm
Press the Stop Alarm Button.
The stop alarm indicator will
turn OFF.
The monitor display will
not disappear.
Emergencies
(Emergency Alarm)
■Responding to the Emergency Button
Monitor: Call indicator flashes and
    emergency alarm is displayed.
Indoor Master
Hardware: Stop Alarm Indicator flashes.
VG-M186D
火災
電源
Emergency
FIRE
WINDOW
POWER
押す
玄関
外出
PUSH
DOOR
ABSENT
Byuun, byuun.
警報音停止 画面表示
Button
非 常
STOPALRM DISPLAY
Someone needs help. Please assist them.*
EMERG.
ハンズフリー
HANDS FREE
Extension
VG-R397N
非常押ボタン
強く
押す
Byuun, byuun.
Someone needs help. Please assist them.*
共同玄関
電 気 錠
室 内 呼
管理人呼
Expansion Speaker
Byuun, byuun.
Someone needs help. Please assist them.*
Alarm indicator flashes if set.
The alarm sound is output if set.
Door Intercom
(with alarm display and
remote test terminal)
or Color Camera Foyer Unit
* You can change the alarm sound to "Byuun, byuun" only. (Consult the company that installed the system.)
■Calls from the Manager's Room during an Emergency Alarm
...The line will automatically connect to the manager's room.
However, if an alarm with a higher priority than the emergency alarm is activated, you will not be connected
automatically.
Stopping the Alarm
Press the Stop Alarm Button.
The stop alarm indicator will
turn OFF.
If the Emergency Button does
not reset automatically when
released, the display will remain
until the Emergency Button is
reset.
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vg-m187d

Table of Contents