Panasonic VG-M186D Operation Manual page 21

Color monitor indoor master for digital pair wiring system
Table of Contents

Advertisement

Security Sensor Operation
(Security Alarm)
■Alarm for Opening a Window or Door
 with a Security Sensor (without a Delay)
Monitor: Security indicator flashes and
    security alarm appears.
Indoor Master
Hardware: Window or foyer security alert
VG-M186D
火災
電源
FIRE
WINDOW
POWER
押す
玄関
外出
PUSH
DOOR
ABSENT
警報音停止 画面表示
非 常
Security Sensor
STOPALRM DISPLAY
EMERG.
Piipoo, piipoo.
A door is open.
ハンズフリー
HANDS FREE
Extension
VG-R397N
非常押ボタン
強く
押す
Piipoo, piipoo.
A door is open.
共同玄関
電 気 錠
室 内 呼
管理人呼
Expansion Speaker
Piipoo, piipoo.
A door is open.
Alarm indicator flashes if set.
The alarm sound is output if set.
Door Intercom
(with alarm display and
remote test terminal)
or Color Camera Foyer Unit
Notice
The alarm will not stop after it is sounded even the window is closed. Press the Stop Alarm Button.
Or, press the Disarmed Button to clear the alert status.
The windows and/or door may be set to alert mode even if they are not fully closed due to the effect of the magnet.
Always make sure that the windows and door are properly closed and locked before enabling the security alert function.
40
Stopping the Alarm
Press the Stop Alarm Button.
The stop alarm indicator will
turn OFF.
The security alert indicator
will continue to flash.
indicator flashes and stop
alarm indicator flashes.
When the Security Sensor is
reset (e.g., by closing the window
or door), the security alert
indicator will stop flashing but
remain lit and the system will
change to alert status.
To reset the alert status, touch
the Disarmed Button. The security
alarm indicator will turn OFF.
■Alarm for Opening a Foyer or Door
 with a Security Sensor (with a Delay)
(After delay time elapses)
Monitor: Security indicator flashes and
    security alarm appears.
Indoor Master
Hardware: Window or foyer security alert
VG-M186D
火災
電源
FIRE
WINDOW
POWER
押す
玄関
外出
PUSH
DOOR
ABSENT
警報音停止 画面表示
非 常
Security Sensor
STOPALRM DISPLAY
EMERG.
(After delay time)
Piipoo, piipoo.
ハンズフリー
HANDS FREE
A door is open.
Extension
VG-R397N
非常押ボタン
強く
押す
(After delay time)
Piipoo, piipoo.
A door is open.
共同玄関
電 気 錠
室 内 呼
管理人呼
Expansion Speaker
(After delay time)
Piipoo, piipoo.
A door is open.
Alarm indicator flashes if set.
Door Intercom
The alarm sound is output if set
(with alarm display and
remote test terminal)
or Color Camera Foyer Unit
■Delay Time
...The alarm sound (puu, puu, puu) will be output.
■Alarms during Delays
...The alarm sound (puu-puu-puu) will be output.
■After Delay
...The alarm sound (piipo, piipo, The door is open) will be output.
■The security alarm will not be output if security is disabled during the delay time.
Notice
The alarm will not stop after it is sounded even if the door or foyer is closed. Press the Stop Alarm Button.
Or, press the Disarmed Button to clear the alert status.
Security Sensor Operation
(Security Alarm)
Stopping the Alarm
Press the Stop Alarm Button.
The stop alarm indicator will
turn OFF.
The security alert indicator
will continue to flash
When the Security Sensor is reset
indicator flashes and stop
(e.g., by closing the door or foyer),
alarm indicator flashes.
the security alert indicator will
stop flashing but remain lit and the
system will change to alert status.
To reset the alert status, touch
the Disarmed Button. The security
alarm indicator will turn OFF.
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vg-m187d

Table of Contents