Multiple Mounting - Epson G3 Series Manual

Scara robot
Hide thumbs Also See for G3 Series:
Table of Contents

Advertisement

3.8.3 Multiple Mounting

■ Install or relocate the Multiple Mounting Manipulator with two or more people.
The Manipulator weights are as follows. Be careful not to get hands, fingers, or
feet caught and/or have equipment damaged by a fall of the Manipulator.
G3-301*M : approx. 14 kg: 31 lb.
G3-351*M : approx. 14 kg: 31 lb.
WARNING
■ When removing the Manipulator from the wall, support the Manipulator, and then
remove the anchor bolts.
extremely hazardous and may result in fall of the Manipulator.
(1)
NOTE
(2)
(3)
G3 Rev.14
Turn OFF the power on all devices and unplug the cables.
Remove the mechanical stops if using them to limit the motion range of Joints #1 and
#2. For details on the motion range, refer to Setup & Operation: 5.2 Motion Range
Setting by Mechanical Stops.
Cover the arm with a sheet so that the arm will not be damaged.
Refer to the figure below and bind the shaft and arm retaining bracket on the base.
Example of Arm
Retaining Posture
Wire tie
Sheet
Hold the bottom of Arm #1 by hand to unscrew the anchor bolts. Then, remove the
Manipulator from the wall.
Setup & Operation 3. Environments and Installation
Removing the anchor bolts without supporting is
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents