Mains Voltage - Panasonic Aquarea PAW-HPM1 Installation And Commissioning Manual

Heat pump manager (hpm)
Table of Contents

Advertisement

Fig. 7.5:
Labelling the basic connection functions
The function of the connections is explained further in the following sections.

7.2.1 Mains voltage

WARNING
Electric shock from electrical voltage!
The device is operated using 230 V AC voltage: Danger to life from electric shock by contact
with conducting parts.
► Switch off power supply prior to starting work on the mains cable.
Fig. 7.6:
Connecting the mains voltage
The HPM controller has its own power supply (230 V AC). This supplies the internal components
of the controller.
Aquarea Heat Pump Manager (HPM) – Manual Part 1: Installation and Commissioning – 12/2014
17
Temp.sensor
18
Temp.sensor
19
Temp.sensor
20
Temp.sensor
21
Temp.sensor
22
Temp.sensor
23
Temp.sensor
24
Temp.sensor
25
Meter/contact
26
Meter/contact
27
0...10V
28
0...10V
29
Ground for 17-28
30
not used
31
not used
32
not used
17
Temp.sensor
18
Temp.sensor
19
Temp.sensor
20
Temp.sensor
21
Temp.sensor
22
Temp.sensor
23
Temp.sensor
24
Temp.sensor
25
Meter/contact
26
Meter/contact
27
0...10V
28
0...10V
29
Ground for 17-28
30
not used
31
not used
32
not used
Installation and Terminal Assignments
N
L
Potential for 13
Relay output
not used
Relay output
Potential for 9+11
Relay output
not used
Relay output
Potential for 5+7
Relay output
not used
Relay output
Potential for 1+3
Relay output
N
16
15
L
14
Potential for 13
Relay output
13
not used
12
11
Relay output
Potential for 9+11
10
Relay output
9
not used
8
7
Relay output
Potential for 5+7
6
Relay output
5
4
not used
Relay output
3
Potential for 1+3
2
Relay output
1
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
N
L
230 V AC