Ametek L Series User Manual page 78

Graphical user interface and software
Table of Contents

Advertisement

L-Series and FCS-18- Graphical User Interface User Manual
A sample data file is shown here as an example. This example uses the
serial number timestamp format. Only 8 data records are shown. Phase B
and C measurements were disabled and therefore do not show.
#1995-08-24 15:30:27#,"User Comment line goes here"
"Time_serial","F","V(A)","I(A)","°(A)","W(A)","VA(A)","PF(A)"
34935.64615,60.0,125.2,0.21,0.00,28,26,1.000
34935.64620,60.0,125.2,0.30,0.00,28,38,1.000
34935.64626,60.0,125.2,0.21,0.00,27,26,1.000
34935.64633,60.0,125.2,0.30,0.00,28,38,1.000
34935.64639,60.0,125.2,0.30,0.00,28,38,1.000
34935.64645,60.0,125.2,0.30,0.00,28,38,1.000
34935.64650,60.0,125.2,0.30,0.00,28,38,1.000
34935.64657,60.0,125.2,0.21,0.00,28,26,1.000
74
California Instruments
Rev D – March 2011