7.4 Transient phase selection

The same transient program can be used for one
phase, two phase or all three phases of a three phase
system. The Phase selection check boxes located in the
bottom right corner of the Transient screen are used for this purpose. If the
connected L-Series unit is a single phase instrument or a three phase unit
with the mode option set to single phase, these controls will be disabled and
only phase A will have a check mark. For three phase units or units with the
phase mode option set to three phase, these controls can be set by the user.
When transient data is downloaded, the status of these phase check
marks is incorporated in the generation of the register program statements
sent to the L-Series unit. Note that the phase information is not stored and
retrieved as part of the general transient information. (See section 7.6) This
allows the same program to be used on a single phase, two phases or all
three.
Rev D – March 2011
L-Series and FCS-18 Graphical User Interface User Manual