L-Series and FCS-18- Graphical User Interface User Manual

7.1 Transient data entry

The transient screen provides a grid like data entry screen that is used to
specify transient type and parameters for each of the sixteen transient
registers. (numbered 0 through 15)

7.1.1 Transient data Entry fields

This data entry grid consists of nine columns representing the following
fields:
Register
Trans.Type
Goto V
48
Number of the transient register that will be used to hold the
transient information. Registers are numbered from 0 to 15.
Transient type field. This is a pulldown field that lists all
available transient types. More details on the various
transient types will follow.
Initial voltage value. For transients that affect voltage, this
value will take effect as soon as the register is recalled. For
voltage sweeps, the Goto V value reflects the start value.
For voltage drops, this field is disabled as a voltage drop
always drops the voltage to zero volt at the start of the
register execution. For voltage steps, this value is the value
set at the output when the transient register is executed. For
Voltage Sag/Surge transients, the Goto V is the value the
voltage will be at for the time period specified in the Delay
field. Whether it represents a sag or a surge will depend on
California Instruments
Rev D – March 2011