Remove screws 9 and 10
assembly
Cover
retaining
screw
Indicator trim
Saddle
clamp
Pump
assembly
Mixer
Temperature
knob
Flow knob
39
7.3.
Remove saddle clamp
retaining screws and clamp.
7.4.
Separate pump assembly
from mixer assembly.
7.5.
Refit in reverse order.
Note! Ensure that the 'O'
seals between the mixer
assembly and the pump
assembly are correctly
seated on each male spigot.
Tip! When refitting the
pump assembly lightly
grease 'O' seals with a
silicone based lubricant.
7.6.
Restore the water supplies
and check for any leaks.
7.7.
Refit the cover by locating
the cover onto the tongue on
the top of the case. Push the
bottom of the cover against
the case, tighten the cover
retaining screw, refit the
temperature knob, indicator
trim and flow knob.
7.8.
Prime the pump, refer to
"Commissioning: Priming
the Appliance". The
adjustable maximum
temperature will also require
to be reset, refer to
"Adjustable Maximum
Temperature Setting".
7.9.
Restore the electrical
supplies.