Mira event Installation, Operation, Maintenance Manual page 33

Manual all-in-one power shower
Table of Contents

Advertisement

Collets
Hose washer
Flexible hose
Release tool
Remove
screws 1 to 10
33
4.2.
Disconnect the electrical
supply cable from the
terminal block and earth
stud. Remove the flexible
hose from the appliance.
4.3.
Remove the three wall fixing
screws,
4.4.
Using the push-fit release
tool, push back and hold the
collets from the supply
pipework, lift the appliance
from the wall to remove the
supply pipework from the
inlet manifold.
4.5.
Remove the drip shield then
remove the inlet manifold,
mixer assembly, pump
saddle clamp and on/off
micro-switch retaining
screws. Remove the micro-
switch with drip shield and
the pump saddle clamp.
4.6.
Whilst gripping the mixer
assembly disconnect the
inlet manifold.