If you experience any difficulty with the installation or operation of your new Electric Shower, please refer to ‘Fault Diagnosis’, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found on the back cover of this guide.
INTRODUCTION Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly. Having done so, keep it handy for future reference. The Mira Sport is an electric shower with separate controls for power selection and temperature/flow adjustment.
DO NOT perform any unspecified modifications to the shower or it’s accessories. When servicing only use Genuine Kohler Mira replacement parts. 10. If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure all electrical connections are tight and that there are no leaks.
PACK CONTENTS CHECKLIST Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included. 1 x Mira Sport 7.5, 9.0 or 9.8 1 x Olive 1 x Compression Nut 3 x Fixing Screws...
WIRING DIAGRAM Thermal Cutout Dual Disc BROWN BROWN Pressure/Power BLACK Selector Switch Solenoid Valve BROWN Power On Neon BLACK Low Flow Neon Load BLUE START/STOP BLACK BROWN BLACK BLUE GREEN Tank Connection GREEN Inlet Connector Internal Wiring Diagram...
Mira Sport range of showers complies with the following European directives: 2006/95/EC Low Voltage Directive, 2004/108/EC EMC Directive. Mira Sport range of showers are high power appliance and are subject to conditional connection. If the main electrical supply fuse is rated less than 80 Amps, the local electricity supply company must be contacted to confirm if the electrical supply is adequate.
INSTALLATION REQUIREMENTS Please read the Important Safety Information and specifications sections at the front of this guide, and the requirements detailed in this section before installing the shower. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Plumbing The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice...
Page 9
15. A full bore/non restrictive servicing valve must be fitted in a readily accessible position adjacent to the shower to facilitate maintenance of the shower. DO NOT use a valve with a loose washer plate (jumper) as this can lead to a build up of static pressure.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Electrical The electrical installation must comply with BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant building regulations, or any particular regulation or practice specified by the local electricity supply company. Ensure that all circuit protection devices, switches and cabling is adequate for the rated current of the shower and that the rating of the electricity supply company fuse and the consumer unit are adequate for the additional demand.
Do not trap green wire. INSTALLATION TEMPLATE Mira Sport Attention Installer Drill and plug* the three Fix appliance to wall. Flush a minimum of 10 holes using template. litres through pipework.
Page 12
Important! Make sure that the inlet earth wire is routed as shown. Failure to do so may cause product malfunction. Connect supply pipe. Do not Feed cable into Case. Fit Earth overtighten! sleeve (not supplied) and strip insulation. Do not twist cable cores. L = BROWN E = GREEN N = BLUE...
COMMISSIONING Before carrying out the commissioning procedure install the Shower Fittings, refer to the Shower Fittings Installation and User Guide. If you are unsure how an electric shower works, please read through the User Instructions section before continuing. Electrical supply is turned Turn control to full cold.
Page 14
Note! A slight hissing sound may be heard from the Mira Sport during operation. High mains water pressure and high shower temperatures will affect the tone. This is quite normal in use.
USER INSTRUCTIONS How Your Electric Shower Works Hot water is produced by passing cold water through a heating tank. The shower has three heater settings. The warmer the shower, the lower the flow rate and vice versa.
Page 16
The Effect of Seasonal Changes * * * For a cold shower select LOW For a summer warm shower select MEDIUM For a winter warm shower select HIGH Adjust the temperature as required The flow rate will adjust automatically The Effect of Other Water Devices Example of how shower temperature stabilizes due to pressure changes.
16. If any of the following conditions occur, isolating switch when not in use. This is isolate the electricity and water supplies for safety and is recommended with all and contact Kohler Mira Customer electrical appliances. Service. DO NOT connect the outlet of the •...
Page 18
Using Your Shower Read the section “User Safety Information” first. Switch on electrical supply. Press START button. Set to desired position. Check water temperature before entering shower. Allow 10-15 seconds for any temperature adjustments to reach the handset. Press STOP button. Shower will A small amount of water may continue to run for a few seconds continue to drain over a few...
FAULT DIAGNOSIS The trouble shooting information tabled below gives details on probable causes and remedies should difficulties be encountered whilst the shower is in operation. Warning! There are no user serviceable components beneath the cover of the appliance. Only a competent trades person should remove the front cover! Heater Power Low/...
Page 20
Heater Power Low/ Symptom Flow Probable Cause Possible Remedy Light Med/ Light High High Due to the rise in Tu r n t h e h e a t e r U n a b l e t o s e l e c t mains water supply selector knob to cool enough...
Page 21
Heater Power Low/ Symptom Flow Probable Cause Possible Remedy Light Med/ Light High Other outlets (e.g. T u r n o f f o t h e r L o w o r n o flow. toilet, garden hose, appliances whilst (cont..) washing machine, shower is in use.
Page 22
Heater Power Low/ Symptom Flow Probable Cause Possible Remedy Light Med/ Light High Insufficient mains Contact local water No change in temperature water pressure. company. between Low/ Medium/High setting. P o s s i b l e f a i l u r e U s e a s u i t a b l e o f f l o w v a l v e , continuity device to...
USER MAINTENANCE WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: DO NOT use the showerhead to There are no user serviceable parts inside the shower. Only clean the shower. qualified, competent personnel If the shower is not to be used for should remove the front cover, a long period, the electrical supply mains connections are exposed...
SERVICING WARNING There are no user serviceable parts inside the shower. Servicing of the shower must only be carried out by qualified, competent personnel following the instructions provided in this guide and those provided with any spare part. Before replacing any parts, ensure that the underlying cause of the malfunction has been resolved.
SPARE PARTS 405.58 Inlet Connector Assembly 406.27 Inlet Filter (with 'O' seal fitted) 416.38 Clamp Bracket (Inlet) 416.41 Thermal Switch 416.48 Latching Switch 416.51 Solenoid Coil 872.01 Microswitch N/O - 2 pin 872.28 Microswitch C/O - 3 pin 1563.500 Heater Tank 7.5 kW 240 V AC (6.85 kW 230 V AC) 1563.502 Heater Tank 9.0 kW 240 V AC (8.2 kW 230 V AC) 1563.504...
Page 26
1563.519 416.41 1563.509 1563.502 1563.500 1563.504 1563.511 1695.017 1563.515 872.28 1563.514 872.01 406.27 1563.507 405.58 1563.516 416.48 1563.517 416.38 1695.018 416.51 Important! Push-fit connectors must be assembled back to back onto terminals of micro-switches. A minimum air gap of 4 mm must be maintained between the connectors after assembly.
ACCESSORIES Genuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guide) or from approved stockists or merchants. Logic Showerhead Holder Everclear Showerhead Shower Seat White - 2.1605.149 White - 2.1616.030...
If your product does not function correctly when you fi rst Fax: 01242 282595 use it, contact your installer to check that it is installed By Post: Mira Customer Services Dept, Cromwell Road, and commissioned in accordance with the instructions in Cheltenham, Gloucestershire, GL52 5EP this manual.