Mira Advance ATL Thermostatic Installation & User Manual

Mira Advance ATL Thermostatic Installation & User Manual

Adjustable temperature limit thermostatic electric shower 9.0 and 9.8 kw
Hide thumbs Also See for Advance ATL Thermostatic:

Advertisement

MIra advance aTL
adjUSTabLe TeMperaTUre LIMIT TherMoSTaTIc
eLecTrIc ShoWer
Installation & User Guide
This product is suitable for mains fed cold water only.
These instructions are to be left with the user
1

Advertisement

Table of Contents
loading

Summary of Contents for Mira Advance ATL Thermostatic

  • Page 1 MIra advance aTL adjUSTabLe TeMperaTUre LIMIT TherMoSTaTIc eLecTrIc ShoWer Installation & User Guide This product is suitable for mains fed cold water only. These instructions are to be left with the user...
  • Page 2: Table Of Contents

    ConTenTs To The Customer ..................3 Important safety Information ..............4 beab care requirements ..............5 Pack Contents ..................6 Dimensions ....................7 Accessories ..................... 7 Specifications ..................8 1. plumbing ..................8 2. electrical ................... 8 3. Standards and approvals ..............8 4.
  • Page 3: To The Customer

    The following separate drain kits are required for the "extra" models: Sdp124T Mira Whale Tray Kit (complete with 50 mm gully) Sdp134T Mira Whale Wet Floor Kit (complete with wet gully for vinyl) This product must only be used with a Whale Shower drain pump (included in the kits listed above).
  • Page 4: Important Safety Information

    1.6 Do noT fit any form of outlet flow control as the outlet acts as a vent for the tank body. Only Mira recommended outlet fittings should be used. 1.7 There are no user serviceable components beneath the cover of this appliance.
  • Page 5: Beab Care Requirements

    The installation should be carried out by an electrician or contractor who is registered, or is a member of, an association such as: • Part P. (Building Regulations.) • NICEIC approved domestic installer. • The Electrical Contractors Association, England and Wales. (ECA.) •...
  • Page 6: Pack Contents

    PACk ConTenTs Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included. 1 x Mira advance aTL 1 x Mira advance aTL 1 x Mira advance aTL Standard or Standard extra...
  • Page 7: Dimensions

    Flex Standard/Memory all dimensions are nominal ACCessoRIes MIRA DCV-h ouTLeT DouBLe CheCkVALVe. Designed to prevent the backflow or backsiphonage of potentially contaminated water, through shower controls which are fitted with a flexible hose as part of the outlet shower fitting.
  • Page 8: Specifications

    This is the minimum pressure required to keep the flow valve closed. standards and Approvals The Mira advance aTL complies with the requirements of the beab care Mark Standard and the relevant directives for ce marking. Patents and Design Registration...
  • Page 9: Shower Performance

    shoWeR PeRFoRMAnCe What affects shower performance? The shower unit's top priority is to keep the desired water temperature constant. To maintain this temperature, the shower may have to automatically change the rate of water flowing through the unit. Any of the following conditions can cause the shower to change the flow rate (force of the shower) in order to keep the temperature constant.
  • Page 10: Installation Requirements

    "Important safety Information" first. 2.1 In a domestic installation, the rating of the electricity supplier’s fuse and the consumer unit must be adequate for the additional demand. all Mira advance aTL electric showers are high power units. voltage drop due to local heavy...
  • Page 11 2.2 The appliance must be earthed by connecting the supply-cable earth conductor to the earth terminal. Any supplementary bonding and supply cable size must conform to Bs 7671. 2.3 as a guide only, and in accordance with Bs 7671 we recommend close circuit protection: I.e.
  • Page 12 Flex extra models only) Inlet clamp air bleed button Wire 75 earth Flow valve ribbon cable (connect to front cover). Tank assembly Splash Guard Flow valve outlet Turbine and connector Inlet Sensor Mira Advance ATL (standard extra and Flex extra models shown)
  • Page 13: Installation

    InsTALLATIon refer to section: "Important safety Information" first. This installation covers all models of the Mira Advance ATL Thermostatic shower. 100 mm electrical supply is determine unit position. remove cover Screw. turned off at the mains. Leave appropriate spaces for maintenance.
  • Page 14 (if applicable). holes only. Fix appliance to wall. Mira Advance ATL standard extra & Flex extra variants only! Find the Whale Shower drain pump jumper position for Mira Transformer and identify it's type number.
  • Page 15: Priming The Unit

    L = broWn IMPoRTAnT! Priming the unit e = Green n = bLUe Make sure electricity is isolated! push down and hold air bleed button to prime appliance until water appears from Failure to shower head. prime will seriously Feed cable into case. Fit earth a f f e c t s h o w e r sleeve and strip insulation.
  • Page 16: Commissioning

    CoMMIssIonInG Important! The Mira advance aTL will adapt it's settings for the individual supply conditions and store this information in it's main memory (during manufacture, this information is factory set using ideal conditions). on initial installation, the unit needs to "learn" about the site conditions and does so during the commissioning cycle.
  • Page 17: Beab Care Compliance

    Within 30 seconds, push and hold down the Flow and start/stop buttons at the same time. on the long beep, release the start/stop button. on the short beep, release the Flow button. Following the Maximum Temperature setting procedure, the appliance automatically starts a Commissioning process to check and adjust to the site conditions.
  • Page 18: Operation

    oPeRATIon 1. how your shower Works 1.1 hot water is produced by passing cold water through a heating tank. The unit constantly monitors the following conditions: • The incoming cold water temperature. • The outgoing shower temperature. • The flow rate of water. •...
  • Page 19: Using The Shower

    as outlined in section "shower Performance", certain conditions can cause the shower's performance to vary. The most common of these conditions is detailed below: 1.2 The effect of other Water Devices Temporary changes in supply conditions can cause reduced flow performance. The selected flow setting may not be available until supply returns to normal.
  • Page 20: Storing The Memory Presets (Memory Control Model Only)

    push start/stop BeFoRe isolating The shower will purge water from the electricity. The flashing light its tank for a few seconds. indicates the shower is shutting down. residual water may drain over a few minutes 3. storing the Memory Presets (Memory Control Model only) Set the shower to the desired push and hold down the desired memory temperature and flow.
  • Page 21: Fault Diagnosis

    • Appliance failure • Supply conditions that may cause unsafe showering. other indicator lights will vary depending upon the fault. If any other fault condition occurs that is not listed in this guide, contact the installer or Mira customer Service dept.
  • Page 22 user Troubleshooting Guide (continued) Resetting the unit This is the first solution to the shower not operating. reset the unit by turning the electricity off and on again at the isolating switch. after turning the electricity back on, the start/stop button will bleep once and flash for approximately 15 seconds before the appliance is ready for use.
  • Page 23: Installer Troubleshooting Guide

    2. Installer Troubleshooting Guide refer to section: 'Important safety Information' first. The following tables are for a competent tradesperson to check against only. Warning! Isolate the electrical and water supply before removing the cover. Warning! Mains connections are exposed when the cover is removed. Warning! refer to wiring diagram before making any electrical connections.
  • Page 24 Cause/Rectification Indicator Display problem with electrical supply, faulty control pcb or faulty relay board. 1. reset the unit. 2. replace control pcb 3. replace relay board. control pcb failure. 1. reset the unit. 2. replace control pcb. Incoming water temperature too high, faulty control pcb or faulty Flow valve assembly.
  • Page 25 Cause/Rectification Indicator Display problem with electrical supply, faulty control pcb or faulty relay board. 1. reset the unit. 2. replace control pcb. 3. replace relay board. Unit is frozen, Outlet Sensor disconnected from relay board or faulty control pcb. 1. reset the unit. 2.
  • Page 26: Maintenance

    MAInTenAnCe user Maintenance - handset Cleaning clean with mild washing up detergent or soap solution. Wipe dry with soft cloth. poor shower performance can be avoided by cleaning the spray plate. Use thumb or soft cloth to wipe rubber nozzles. The handset shall be descaled regularly to stop the handset getting blocked.
  • Page 27: Wiring Diagram

    WIRInG DIAGRAM control board cn10 cn12 relay cn11 board 230/240 v ac only outlet Temperature Sensor pump driver board one Shot Thermal Switch heater Tank (Fitted to Standard extra and Flex extra models only.)
  • Page 28: Spare Parts

    sPARe PARTs 405.58 Inlet connector assembly 406.27 Inlet Filter. 1643.100 Thermal Trip. 1643.101 Tank assembly 9 kW/230 v 9.8 kW/240 v (earth wire not included). 1643.102 Tank assembly 8.2 kW/230 v 9 kW/240 v (earth wire not included). 1643.103 Terminal block/earth Wire/neutral Wire. 1643.104 relay board (including screws).
  • Page 29 sPARe PARTs 1643.104 1643.111 1643.103 1643.112 1643.105 1643.144 405.58 1643.100 406 27, c 1643.108 1643.109 1643.110 1643.101 1643.102 1643.114 1643.106 1643.107 1643.105 1643.144...
  • Page 30: Notes

    noTes...
  • Page 31 noTes...
  • Page 32: Customer Service

    Our Service Force is available to provide a quality service Damage or defects if the product is taken apart, repaired or at a reasonable cost. You will have the assurance of a Mira modifi ed by any persons not authorised by Mira Showers trained engineer/agent, genuine Mira spare parts and a or our approved agents.
  • Page 33 Electric Showers Digital Showers Mixer Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more Stuart Turner Shower Pumps Salamander Shower Pumps...

Table of Contents