10. Micro-switches
On/off Micro-switch
Warning! Isolate the electrical and water supply to the appliance before
proceeding.
Disconnect wiring by pulling on body of spade connector only and not the wire
itself.
10.1. Remove on/off micro-switch
retaining screw and remove
the drip shield from the on/off
micro-switch.
10.2. Remove electrical supply
wiring to on/off micro-switch.
10.3. Renew on/off micro-switch.
10.4. If renewal of torsion spring or
actuator is required, fit
torsion spring on to actuator
and fit the assembly over
appropriate spigots.
10.5. Fit the new on/off micro-
switch in reverse order.
Torsion spring
44
Remove screw 8 only
Drip shield
Electrical
supply wiring
Actuator