6. Mixer Assembly Renewal

The following procedure can be applied for cleaning or replacing the mixer
assembly.
Warning! Isolate the electrical and water supply to the appliance before
proceeding.
6.1.
Use the push-fit release tool
to lever off the flow knob,
indicator trim and temperture
knob. Unscrew the cover
retaining screw and remove
the cover by pulling the
bottom of the cover in an
outward and upward direction.
Remove the flexible hose
from the mixer assembly
outlet.
6.2.
Remove the on/off micro-
switch retaining screw and
the on/off micro-switch with
drip shield. Do not remove
pcb wiring from on/off micro-
switch.
Remove the other drip shield
and lever off the smaller
micro-switch.
Do not remove the pcb
wiring.
6.3.
Loosen pump saddle clamp
retaining screws and saddle
clamp. Remove the inlet
manifold retaining screws.
Remove the mixer assembly
retaining screws.
Do not remove electrical
supply wiring.
Cover
retaining
screw
36
Temperature
knob
Flow knob
Indicator
trim
Hose washer
Flexible hose
Remove screws 1 to 8
Loosen screws 9 and 10