ProMinent DULCOMARIN 3 Compact Assembly And Operating Instructions Manual page 60

Multi-channel measuring and control system
Table of Contents

Advertisement

Assembly and installation
Tab. 12: If you use a sensor without fixed cable or wish to extend the fixed cable, you must use the pre-
assembled sensor cables:
Accessories
Measuring line LF 1 m:
Measuring line LF 3 m:
Measuring line LF 5 m:
Measuring line LF 10 m:
Sensor
Connector
LFTK1FE3m
Fixed cable
0.25 mm
m, shielded
LFTK1FE5m
Fixed cable
0.25 mm
5 m, shielded
LFTK1-DE
DIN 4-pin
LFTK1-1/2
DIN 4-pin
LF1-DE
DIN 4-pin
LFT1-DE
DIN 4-pin
LFT1-1/2
DIN 4-pin
LMP01
DIN 4-pin
LMP01-HT
DIN 4-pin
LMP01-TA
Fixed cable
0.34mm
5 m, shielded
LMP001
DIN 4-pin
LMP001-HT
DIN 4-pin
LM1
DIN 4-pin
LM1-TA
Fixed cable
0.34 mm
5 m, shielded
LMP1
DIN 4-pin
LMP1-HT
DIN 4-pin
LMP1-TA
Fixed cable
0.34 mm
5 m, shielded
60
Cell constant
T-correction
element
Cell constant
(1/cm)
1.00
Pt1000
2
, 3
1.00
Pt1000
2
,
1.00
Pt1000
1.00
Pt1000
1.00
-
1.00
Pt100
1.00
Pt100
0.10
Pt100
0.10
Pt100
0.10
Pt100
,
2
0.01
Pt100
0.01
Pt100
1.00
-
1.00
-
,
2
1.00
Pt100
1.00
Pt100
1.00
Pt100
2
,
Part number
1046024
1046025
1046026
1046027
Selection of the connected sensor
All of the sensor-dependent settings are reset to
the [DEFAULT] values when changing the con‐
nected sensor.
Max. temp.
(°C)
80
80
80
80
80
80
80
70
120
70
70
120
70
70
70
120
70
Measuring
Measuring
range κ min
range κ max
(Unit)
(Unit)
0.01 mS/cm
20 mS/cm
0.01 mS/cm
20 mS/cm
0.01 mS/cm
20 mS/cm
0.01 mS/cm
20 mS/cm
0.01 mS/cm
20 mS/cm
0.01 mS/cm
20 mS/cm
0.01 mS/cm
20 mS/cm
0.1 uS/cm
500 uS/cm
0.1 uS/cm
500 uS/cm
0.1 uS/cm
500 uS/cm
0.01 uS/cm
50 uS/cm
0.01 uS/cm
50 uS/cm
0.1 mS/cm
20 mS/cm
0.1 mS/cm
20 mS/cm
0.1 mS/cm
20 mS/cm
0.1 mS/cm
20 mS/cm
0.1 mS/cm
20 mS/cm

Advertisement

Table of Contents
loading

Table of Contents