Commissioning
Description of procedure for starting
up a swimming pool for the first time
(single pool)
Tab. 17: Description of procedure for starting up a swimming pool for the first time (single pool)
Step
Process
1
Switch on device
2
Configuration of DM3 Set language.
3
Configuration of DM3 Set date and time.
4
Configuration of DM3 Enter system data (pool name).
5
Configuration of DM3
6
Configuration of DM3 Enter circulation capacity.
7
Configuration of DM3 Assign sensors to pool.
8
Configuration of DM3 Assign pump to pool.
9
Configuration of DM3 Assign a function (increase value/
10
Start basic chlorina‐
tion
11
Chlorine measure‐
ment
12
Calibrate
13
Start control
14
Closed-loop control
15
Maintenance
16
Final log
100
The following requirements must be met:
mechanical assembly carried out,
n
hydraulic installation carried out,
n
circulating pump running,
n
electrical installation carried out,
n
CAN connectivity carried out,
n
communication interfaces configured.
n
Details
Switch on supply voltage.
Pool settings
n
Pool geometry
n
Pool volume
n
decease value) to the pumps.
Check control parameters and adapt
as necessary.
Perform basic chlorination, using a
theoretically calculated value.
Sensors must run in.
Calibrate sensors
Start control on DM3.
The system runs fully automatically.
Check control parameters, if neces‐
sary perform fine adjustment and
recalibrate the system.
Documentation of all control parame‐
ters incl. assignment of components
with serial numbers in the respective
pools.
Who
Duration
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
approx. 2 min
(whirlpool) to
approx. 30 min
(sports pool)
Service
approx. 1 hour
Service
Service
Service
min. 2 h to 1 day
Service
Service