13.4

Factory settings for ORP measured variable

ORP measured variable
Name
Controller set‐
Control param‐
tings
eter
Control type
Control direc‐
tion
Setpoint
Display range
(bar graph)
Limit values
(advance
warning)
Limit values
(advance
warning)
Alarms (alarm
relay switches)
Alarms (alarm
relay switches
and control
stops) *
Time for which
limit value is
exceeded,
range 1 ... 1800
s
Recorder 2 h
Recorder over‐
view
* The control stops when controlling using the ORP value. The control does not stop if controlling via a
chlorine sensor.
Normal mode
inactive
PID
On one side; increae
value
770
Xp
50
Ti
0 s (P) 3000 s (PI/PID) 0 s (P) 3000 s (PI/PID)
Td
0 s (P/PI/PID)
min.
600
max.
1000
min.
750
max.
850
min.
750
max.
820
300 s
min.
dynamic
max.
dynamic
min.
600
max.
900
Factory settings of device
Eco!Mode
®
inactive
PID
On one side; increase
value
750
50
0 s (P/PI/PID)
600
1000
740
790
730
800
300 s
dynamic
dynamic
600
900
Superchlori‐
nation
prohibited!
97