Ikegami HLM-960WR Operation Manual page 25

Full hd multi format lcd color monitor
Table of Contents

Advertisement

IN / OUT B
SDI CH-C input
SDI CH-D CH-B output
IN / OUT C
SDI CH-C input
SDI CH-D CH-C output
IN / OUT ABC
SDI CH-C input
SDI CH-D CH-A/B/C output
Default setting is OUT AB.
Setting the TEST PATTERN
Set the TEST signal to be displayed.
It can be set to the following 7 patterns.
Gray scale with pluge
Color Bar
100% Window
20% Gray
Pluge
Full Color Bar
-6.8 0%&100 109%
Refer to 2-1
for the pattern.
Default setting is the GRAY SCALE.
Setting the MIX TEST SIGNAL
By mixing the pluge signal (-2%/0%/+2%) and the
100% to 109% signal into the image, you can ad-
just the image in real time by checking if white
part is not saturated due to the CONTRAST ad-
justment for the over 100% signal or if there is no
crushed black effect cased by the BRIGHTNESS
adjustment.
This monitor automatically turns off the Mix Test
signal display when the front volume is not oper-
ated for approximately one minute.
This function can be assigned to a function switch
on the front panel.
HLM-960WR / 1760WR / 2460W
* Only SDI signals are supported.
Default setting is OFF.
Superimpose -2%, 0%, and
+2% of pluge signal.
-2%
0
- -
15
+2%
Superimpose 100 to 109% of
brightness signal.
104
100
102
106
109 %