Getting Started

UNDERSTANDING SENSOR HEIGHT (HEIGHT)

This is a critical setting for EchoPod
of the tank. The value must take into account the shape of the tank and any risers, fittings, structures or
extensions associated with the tank or the installation (see examples below). The reference point for definition
of the Sensor Height is always the bottom of the mounting nut.
Simple Vertical Tank
Simple Open Top Tank
Simple Horizontal Tank
MN310140 Rev A3
(continued)
®
. Sensor Height (SH) defines the location of the sensor from the bottom
Dome Top Raises HEIGHT
Sensor Extends into Sump
Riser Elevates HEIGHT
Step Two
Sensor Off-center
Changes HEIGHT
Cone Bottom
Elevates HEIGHT
Mounting Fixture
Elevates HEIGHT