How To Reverse The Current Output (Rev Ma) - FlowLine EchoPod UG06 Series Manual

Hide thumbs Also See for EchoPod UG06 Series:
Table of Contents

Advertisement

Display Appendix
HOW TO REVERSE THE CURRENT OUTPUT
The factory setting for EchoPod
requires this output to be reversed (20mA at bottom and 4mA at top), then use the REV MA setting to reverse
the current output.
With REV MA set to NORM (factory default), 4mA will be at the bottom and 20 mA at the top of the tank.
With REV MA set to REV, 20mA will be at the bottom and 4mA at the top of the tank.
1. In
TOP-LEVEL
OUTPUT.
2. Select REV MA.
3. Select 4 BOTT or 4 TOP.
a. Press and hold OK on the selected
setting for 2 seconds then release.
b. To cancel REV MA, Select EXIT.
4. Select EXIT to return to TOP-LEVEL MENU.
|
46
(continued)
®
has 4mA set at the bottom of the tank and 20mA at the top. If the application
MENU
mode,
select
Section Eight
MN310140 Rev A3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents