Webcal ® Vs. Display Configuration - FlowLine EchoPod UG06 Series Manual

Hide thumbs Also See for EchoPod UG06 Series:
Table of Contents

Advertisement

Getting Started
®
WEBCAL
VS. DISPLAY CONFIGURATION
®
EchoPod
can be configured using either the free WebCal
module. Either method will accomplish the goal of sensor configuration. Changes to the configuration can be
made using the alternative method. Upon implementing one methodology, it is recommended to complete the
configuration before using the other methodology in making any adjustments.
®
EchoPod
can be configured before installation or after installation. The transmitter features non-volatile
memory, so any settings configured before installation will not be lost when the sensor is powered down. To
start, the following information is required:
Basic Tank Information
o HEIGHT (Sensor Height) – Distance from
the bottom of the tank to the bottom of the
sensor.
o FILL-H (Fill-Height) – Distance from the
bottom of the tank to the fill-height of the
liquid.
Power:
o Provide input power to the EchoPod
Note: The HEIGHT and Fill-Height (FILL-H) settings also determine the 4 to 20 mA current span. The
HEIGHT setting determines the 4mA position and the FILL-H setting determines the 20 mA position.
|
10
(continued)
®
software and USB
®
Step Two
®
Fob or with the internal display
MN310140 Rev A3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents