How To Access Diagnostic Information - Baldor 22H series Installation & Operating Manual

Line regen ac flux vector control vector drive
Table of Contents

Advertisement

Section 1
General Information

How to Access Diagnostic Information

Action
Apply Power
Display mode showing motor
speed.
Press DISP key 6 times
Scroll to Diagnostic Information
screen
Press ENTER key
Access diagnostic information.
Press DISP key
Display showing control
temperature.
Press DISP key
Display showing bus voltage.
Press DISP key
Display showing % overload
current remaining.
Press DISP key
Display showing opto inputs &
outputs states.
0=OPEN, 1=CLOSED.
Press DISP key
Display showing actual drive
running time.
Press DISP key
Display showing operating zone,
voltage and control type.
Press DISP key
Display showing continuous
amps; PK amps rating; amps/volt
scale of feedback, power base ID.
Press DISP key
Display showing which Group1 or
2 expansion boards are installed
and recognized.
Press DISP key
Display showing motor shaft
revolutions from the REV home
set point.
Press DISP key
Display mode showing parameter
table selected.
Press DISP key
Display showing software version
and revision installed in the
control.
Press DISP key
Displays exit choice.
5-6 Troubleshooting
Description
Display
Logo display for 5 seconds.
No faults present. Local keypad
mode. In remote/serial mode,
disable drive then press local for
this display.
Diagnostic Access screen.
First Diagnostic Information
screen.
XXXV
Opto Inputs states (Left);
Opto Outputs states (Right).
HR.MIN.SEC format.
ID is displayed as a hexadecimal
value.
Press ENTER to exit diagnostic
information.
Comments
MN722

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents