Section 1
General Information
FAULT MESSAGE
Current Sens FLT
DC Bus High
DC Bus Low
Encoder Loss
External Trip
Following Error
GND FLT
INT Over-Temp
Invalid Base ID
Inverter Base ID
Line Regen FLT
Logic Supply FLT
Lost User Data
Low INIT Bus V
Memory Error
New Base ID
No Faults
No EXB Installed
Over Current FLT
Overload - 1 min
Overload - 3 sec
Over speed
P Reset
PWR Base FLT
Resolver Loss
Torque Prove FLT
User Fault Text
MN722
Table 5-2 Power Output Control Board Fault Messages
Defective phase current sensor or open circuit detected between control board and current
sensor.
Bus over voltage condition occurred.
Bus under voltage condition occurred.
Encoder coupling slipping or broken; noise on encoder lines, encoder power supply loss or
defective encoder.
An open circuit on J1-16 typically indicating an external over temperature condition.
Excessive following error detected between command and feedback signals.
Low impedance path detected between an output phase and ground.
Temperature of control heatsink exceeded safe level.
Control does not recognize power base ID.
Control board installed on power base without current feedback.
Indicates a converter section fault.
Logic power supply not working properly.
Battery backed RAM parameters have been lost or corrupted.
When fault cleared (Reset), the control should reset to factory preset values.
Insufficient bus voltage on startup.
EEPROM error occurred. Contact Baldor.
Control board sensed a different power base since last time it was powered up.
Fault log is empty.
Programmed parameter requires an expansion board.
Instantaneous over current condition detected by bus current sensor.
Output current exceeded 1 minute rating.
Output current exceeded 3 second rating.
Motor RPM exceeded 110% of programmed MAX Motor Speed.
Power cycled before the residual Bus voltage reached 0VDC.
Desaturation of power device occurred or bus current threshold exceeded.
Resolver feedback problem is indicated (if resolver used).
Unbalanced current between all 3 motor phases.
Custom software operating fault occurred.
DESCRIPTION
Troubleshooting 5-3