Motion 4000
General Settings Log
OPTIONS
Controller Type:
Simplex / Local or Duplex?
Operation:
Top Landing Served (This car)?
HC-RDR Board on this Car (This car)
Car Serves Frnt/Flr (This car)?
Car Serves Rear/Flr (This car)?
Top Landing Served (Other car)?
HC-RDR Board on this Car (Other car)
Other Car Serves Frnt/Flr?
Other Car Serves Rear/Flr?
Parking Floor
Alt. Parking Floor
Secondary Park Floor
Lobby Floor
Car Identifier
Serial COP Board HC-CPI?
Discrete PIs on UIO?
Dedicated PI Board?
Serial Cartop Door CNTRL?
Disable Local Hall Calls?
Fire Service Operation?
Fire Phase 1 Main Floor
Fire Phase 1 Alt. Floor
Fire Service Code
nd
Fire Phase 1, 2
Alt Landing
Will This Car Run on PH2?
Bypass Stop Sw. on Phase 1?
Honeywell Fire Operation?
NYC Fire Phase 2 w/ ANSI 89?
White Plains, NY Fire Code?
Mass 524 CMR Fire Code?
ASME A17.1A 200x Addenda?
Disable DPM on Fire PH.2?
Low Voltage Fire Sensor?
Latch Flashing Fire Hat?
Nudging?
Stuck Photo Eye Protection?
Sequential Door Oper.(F/R)?
Car Call Cancels Door Time?
Nudging During Fire Phase 1?
Retiring Cam Option?
Pre-Opening?
Mechanical Safety Edge?
Nudging Output/Buzzer Only?
Program Mode (F1) Parameter Settings Record
___ Hydro (M2000) ___ Traction (M4000)
___ Simplex ___ Local ___ Duplex
___ Sel. Coll. ___ Single Button
___ Single Auto PB
_____ Yes
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32
_____ Yes
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32
Set first car to A, next car to B, etc.
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ None
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
_____ Yes
CURRENT VALUES
BASIC FEATURES
______ No
______ No
______ No
______ No
______ No
______ No
______ No
FIRE SERVICE
______ No
______ No
______ No
______ No
______ No
______ No
______ No
______ 2005
______ 2007
______ No
______ No
______ No
DOOR OPERATION
______ No
______ No
______ No
______ No
______ No
______ No
______ No
______ No
______ No
General Settings Log
NEW VALUES
___ Hydro (M2000) ___ Traction (M4000)
___ Simplex ___ Local ___ Duplex
___ Sel. Coll. ___ Single Button
___ Single Auto PB
_____ Yes
______ No
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32
_____ Yes
______ No
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32
Set first car to A, next car to B, etc.
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ None
______ 2005 ______ 2007
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
_____ Yes
______ No
A