Access Security; Password; Setting Parameters To Default Values - Motion Control Engineering Motion 4000 Manual

Traction elevator controller
Table of Contents

Advertisement

Motion 4000

Access Security

Access security is an option. When access security is active, you are required to enter a pass-
word before parameters can be adjusted.

Password

Program mode and System mode may be secured by an 8-
digit, alpha-numeric code. If this is the case, when either
mode is selected using the Function switches, the LCD will
show:
To enter a password:
• N: to select a digit
• +: to increment value
• -: to decrement value
• S: Enter (check against valid password)
Once a valid code is entered, access is granted. The password will not have to be re-entered until
the password timer expires.
Note
If Passcode Request appears on the LCD, a passcode is
required in order to run the elevator on any mode of opera-
tion other than Inspection. See
more information.
on page
4-56.

Setting Parameters To Default Values

There are occasions when it is necessary to reset system parameters to default values:
• MC-MPU software is changed.
• RAM memory is corrupted (lightning strikes can sometimes cause this)
To reset to default values:
1. Place the car on Machine Room Inspection.
2. Place function switches F1, 3, 5, and 7 in the Up position.
3. Press all four push buttons (N, S, +, -) at the same time.
After resetting parameters to their defaults, you will need to set up system parameters again.
Passcode Request Menu
Please refer to "Passcode Request Menu"
Access Security
for
4
4-5

Hide quick links: