Setting The Distance Adjustment - GRAPHTEC FC5100A-75 User Manual

Grit-rolling cutting plotter
Table of Contents

Advertisement

108
Setting the DIS-
TANCE ADJUST-
MENT
Ad v an ce d Fu n ct i on s an d S e t ti ng s : A UT O R E G . M A RK - Au t o Re gi st r a ti on M ar k S e n so r
The DISTANCE ADJUST function allows you to specify the method to precisely
adjust the distance between the registration marks. The distance between regis-
tration marks is automatically corrected to a value.
There are two types of distance adjustment methods available, manual and
auto. When manual is selected, you must enter the distance between the registra-
tion marks to set the scaling factor, therefore, you must known the distance
between the registration marks. When auto is selected, the plotter sets the scaling
factor automatically by digitizing the distance between the registration marks and
by setting the resolution. You may select 5mm resolution, 10mm resolution or
50mm resolution.
• Press the ALIGNMENT key.
• Press the F1 key to select AUTO REG. MARK.
• Press the F4 key to select DISTANCE ADJUST.
• Press the F2 ( DISTANCE ADJUST) key to display the following screen.
• The item marked with the asterisk is the current setting.
To turn off distance adjustment (manual input), press the F2 key (OFF).
For Custom distance adjustment, press the F3 key (CUSTOM).
For Standard distance adjustment, press the F4 key (STANDARD).
• If the settings are OK, press the Enter key.
• If distance adjustment is CUSTOM, the following screen is displayed.
AUTO REG.
MANUAL>*
MARK SCAN
MARK
OTHER
SETUPS>*
DISTANCE
ADJUST>*
DISTANCE ADJUST
CUSTOM
STANDARD*
DISTANCE ADJUST
MARK>*
SKIP>*
AUTO>*
MODE>*
TYPE>*
OFF*
5mm*
10mm*
50mm*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc5100a-130Fc5100a-100Fc5100a-150