Expand - Expanding The Cut Area - GRAPHTEC FC5100A-75 User Manual

Grit-rolling cutting plotter
Table of Contents

Advertisement

EXPAND - Expanding the Cut Area

EXPAND mode allows you to both widen and narrow the cutting area. The cut-
ting area is automatically determined by the position of the pinch rollers when the
plotter is initialized.
Select EXPAND when cutting a pattern that is nearly as wide as the media, and
you do not mind the footprint caused by the grit rollers along the edges of the pat-
tern. However, this function can be used to protect the cut pattern from the foot-
print by narrowing the cut area.
When the parameter of the EXPAND mode is set to zero (default), the limit of the
cutting area is set at 1mm from the inside edge of the pinch roller tracks. The
parameter of the EXPAND mode ranges from -10 to +10 mm. This parameter rep-
resents the allowable range on each side of the cutting area.
A positive setting indicates the limit of both sides move toward the outside of the
cutting area while a negative setting indicates the limit of both sides move toward
the inside of the cutting area.
For example, a setting at +5 allows a 10mm wider cutting area than the size of
the default cutting area, whereas a setting at -5 allows a 10mm narrower cutting
area than the default size cutting area.
CAUTION: In the case of setting the positive figure for the parameter, be sure to load the
media on to the plotter accurately so that the media does not skew during cut-
ting. The cutter blade may damage the cutting mat if the media skews.
CAUTION: In the case of setting +8 mm or more, be sure to set the Initial Blade Control
Position to "2mm below". The cutter blade will damage the cutting mat if it is set
to "OUTSIDE". See Initial Blade Control Position in the Background Set-
ting.
NOTE:
This function should be set before the cutting/plotting job is started since
changing the setting of this mode will cause the plotter to initialize which will
clear all data in the buffer.
• Press the MENU key to select MENU mode.
• Press the NEXT key two times.
• Press the F2 key to select AREA PARAMETERS.
A dv an ce d F un c ti on s an d S et ti n gs : E X P A ND - E x p an d in g t he C ut Are a
INTERFACE>.
AREA
PARAMETERS>.
FUNCTION
1>.
FUNCTION
2>.
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc5100a-130Fc5100a-100Fc5100a-150

Table of Contents