A-10
Specifications
% of Rated
Power Output
20
40
60
80
100
Publication 1394-5.20 — July 2001
System Modules
The power dissipation (in watts) of the system module types is shown
below.
% of Rated Power Output
20
40
60
80
100
Axis Modules
The power dissipation (in watts) of the axis modules is shown below:
Total
AM03
AM04
AM07
24
27
33
30
36
48
36
45
63
42
54
78
48
63
93
1
The AM50/75 are designed to mount with the rear heat sink extended outside the customer-supplied enclosure. If
the modules are mounted entirely inside the customer supplied enclosure, the full power dissipation is inside the
cabinet.
2
The AM50/75-IH are designed to mount entirely inside the customer-supplied enclosure.
Internal Shunt Resistor for the 5 and 10 kW System
When the shunt resistor inside 1394C-SJT05-D and 1394C-SJT10-D
system module is active, some additional power will be dissipated at
the system module. Its maximum dissipation is 200W. Most
applications will use less than 10% of this capacity.
The:
Rating of the internal shunt resistor
Resistance of the internal shunt resistor
Power Dissipation (in watts)
1394C-SJT05-D
1394C-SJT10-D
66
70
70
77
73
84
77
81
80
98
Power Dissipation (in watts)
Inside Cabinet
1
1
AM50
AM75
and
and
AM50
2
2
AM50-IH
AM75-IH
56
85
18
95
145
18
139
212
18
183
279
18
227
346
18
Is:
200W continuous, 40,000W peak (two second
maximum on time)
16 ohms
1394C-SJT22-D
100
150
200
250
300
Outside Cabinet
1
1
1
AM75
AM50
18
38
18
77
18
138
18
165
18
209
1
AM75
67
127
194
261
324