No.
Parameter
Description
13
Communic
The standards of
ation
certain countries and
interrupt
regions require that
shutdown
the SUN2000 must
shut down after the
communication is
interrupted for a
certain time.
14
Communic
Specifies the duration
ation
for determining
interruptio
communication
n duration
interruption, and is
used for automatic
shutdown for
protection in case of
communication
interruption.
15
Soft start
Specifies the duration
time
for the power to
gradually increase
when the SUN2000
starts.
16
Hibernate
The SUN2000
at night
monitors PV strings at
night. If Hibernate at
night is set to Enable,
the monitoring
function of the
SUN2000 will
Issue 02 (2018-10-15)
Unit
connection mode
of the PV strings.
When the PV
strings connect to
one another in
parallel outside the
inverter and then
connect to the
inverter
independently
(fully parallel
connection), set
this parameter to
All PV strings
connected.
N/A
min
s
N/A
Copyright © Huawei Technologies Co., Ltd.
Default
Value Range
Value
Disable
Disable
Enable
30
[1, 120]
20
[20, 1800]
Disable
Disable
Enable
7 Man-Machine Interactions
Remarks
If Communication
interrupt shutdown
is set to Enable and
the SUN2000
communication has
been interrupted for
a specified time (set
by Communication
interruption
duration), the
SUN2000 will
automatically shut
down.
N/A
N/A
N/A
79