SUN2000-60KTL-M0
User Manual (Europe Edition)
Alarm
Alarm
Alarm
ID
Name
Severity
2066
License
Warning
Expired
61440
Faulty
Minor
Monitor
ing Unit
2085
Built-in
Minor
PID
Operatio
n
Abnorm
al
Issue 02 (2018-10-15)
Cause
1. The privilege certificate has entered
the grace period.
2. The privilege feature will be invalid
soon.
1. The flash memory is insufficient.
2. The flash memory has bad sectors.
1. The output resistance of PV arrays
to ground is low.
2. The system insulation resistance is
low.
Contact Huawei technical support if all failure analysis procedures listed above are completed and the
fault still exists.
Copyright © Huawei Technologies Co., Ltd.
8 Maintenance
Measures
1. Apply for a new certificate.
2. Load the new certificate.
Turn off the AC output switch and
DC input switch, and then turn
them on after 15 minutes. If the
fault persists, replace the
monitoring board or contact
Huawei technical support.
Cause ID = 1
1. Turn off the AC output
switch and then the DC
input switch. After 15
minutes, turn on the AC
output switch and then the
DC input switch.
2. If the fault persists, contact
your supplier/Huawei
technical support.
Cause ID = 2
1. Check the output resistance
of PV arrays to ground. If
there is a short circuit or
lack of insulation, rectify it.
2. If the fault persists, contact
your supplier/Huawei
technical support.