2.
Cable Specifications
Cable Type
PV cable that meets the
1100 V standard
Cables with high rigidity, such as armored cables, are not recommended, because poor contact
may be caused by the bending of the cables.
Procedure
Step 1 Prepare positive and negative connectors.
Use the Amphenol Helios H4 PV connectors provided with the SUN2000. If the terminals are
lost or damaged, purchase the PV connectors of the same model. The device damaged caused
by incompatible PV connectors is not covered under any warranty or service agreement.
Issue 02 (2018-10-15)
Evenly distribute DC input power cables on the DC input terminals controlled by the two
DC switches.
Maximize the number of connected MPPT circuits.
Copyright © Huawei Technologies Co., Ltd.
Conductor Cross-Sectional Area
(mm
)
2
Range
4.0–6.0 (12–10
AWG)
5 Electrical Connections
Recommended
value
4.0 (12 AWG)
Cable Outer
Diameter (mm)
4.5–7.8
44