SUN2000-60KTL-M0
User Manual (Europe Edition)
No.
Parameter
Description
6
Power
If Power quality
quality
optimization mode is
optimizatio
set to Enable, the
n mode
inverter output current
harmonics will be
optimized.
7
PV module
This parameter is used
type
to set different types
of PV modules and
the shutdown time of
the concentration PV
modules. If the
concentration PV
modules are shaded,
the power drops
drastically to 0 and
the SUN2000 shuts
down. The energy
yield would be
affected since it takes
too long for the power
to resume and
SUN2000 to restart.
The parameter does
not need to be set for
crystalline silicon and
filmy PV modules.
Issue 02 (2018-10-15)
Unit
during the reactive
power
compensation at
night.
N/A
N/A
Copyright © Huawei Technologies Co., Ltd.
Default
Value Range
Value
Enable
Disable
Enable
Crystalline
Crystalline
silicon
silicon
Film
CPV 1
CPV 2
7 Man-Machine Interactions
Remarks
N/A
If PV module
type is set to
Crystalline
silicon or Film,
the SUN2000
automatically
detects the power
of PV modules
when they are
shaded and shuts
down if the
power is too low.
When the
concentration PV
modules are
used:
If PV module
type is set to
CPV 1, the
inverter can
quickly
restart in 60
minutes when
the input
power of PV
modules
drops
drastically
due to
shading.
If PV module
type is set to
CPV 2, the
inverter can
quickly
restart in 10
minutes when
the input
power of PV
modules
77