Huawei SUN2000-60KTL-M0 User Manual page 84

Three-phase grid-tied pv string inverter
Hide thumbs Also See for SUN2000-60KTL-M0:
Table of Contents

Advertisement

SUN2000-60KTL-M0
User Manual (Europe Edition)
No.
Parameter
Description
8
Crystalline
The PID effect may
silicon PV
result in the power
compensati
attenuation of PV
on mode
modules, which is
mainly caused by the
DC voltage between
PV modules and the
ground. Enabling this
setting lowers the DC
voltage between PV
modules and the
ground by reducing
the impedance on the
input side to the
ground.
9
Built-in
Specifies the
PID
operation mode of the
running
SUN2000 built-in
mode
PID.
10
PID
Specifies whether to
nighttime
enable the PID
off-grid
nighttime off-grid
repair
repair.
11
PID
Specifies whether to
daytime
enable the PID
off-grid
daytime off-grid
repair
repair.
12
String
Specifies the
connection
connection mode of
mode
PV strings.
Issue 02 (2018-10-15)
Unit
N/A
N/A
N/A
N/A
N/A
When the PV
strings connect to
the inverter
separately (fully
separate
connection), there
is no need to set
this parameter.
The inverter can
automatically
detect the
Copyright © Huawei Technologies Co., Ltd.
Default
Value Range
Value
Disable
Disable
output
output
PV– positive
offset
PV+
negative
offset
Repair
Disable
Repair
Enable
Disable
Enable
Disable
Disable
Enable
Automatic
Automatic
detection
detection
All PV
strings
separated
All PV
strings
connected
7 Man-Machine Interactions
Remarks
drops
drastically
due to
shading.
This parameter is
displayed only if PV
module type is set
to Crystalline
silicon.
This parameter is
displayed only for
the models that
support Built-in
PID repair.
This parameter is
displayed only if
Built-in PID
running mode is set
to Repair.
This parameter is
displayed only if
Built-in PID
running mode is set
to Repair.
N/A
78

Hide quick links:

Advertisement

Table of Contents