3.10.4. Frame Sizes 6 & 7
3.11. Routine Maintenance
The drive should be included within the scheduled maintenance program so that the installation maintains a suitable operating
environment, this should include:
Ambient temperature is at or below that set out in section 10. 1 . Environmental.
Heat sink fans freely rotating and dust free.
T he Enclosure in which the drive is installed should be free from dust and condensation; furthermore ventilation fans and air filters
should be checked for correct air flow.
Checks should also be made on all electrical connections, ensuring screw terminals are correctly torqued; and that power cables
have no signs of heat damage.
www.invertekdrives.com
Using a suitable flat blade
screwdriver, rotate the six retaining
screws indicated until the screw slot
is vertical.
Version 3.00 | Optidrive P2 User Guide | 19