3.7.5

Configuring VersaMax Module Parameters

After adding VersaMax modules to the remote node, the parameters for each must be configured. For all
VersaMax modules, this includes configuring a set of basic parameters (such as: Reference Address, Length,
Scan Set, Carrier, Report Faults). Configuration details for those basic parameters are provided in the
Configuration chapter of the VersaMax PROFINET Scanner Manual, GFK-2721.
3.7.5.1
Configuring Analog Modules Requiring Jumper Settings
The following VersaMax analog modules use jumpers to select their voltage / current operation or output
defaults mode.
IC200ALG230
Analog Input Module, 12-bit Voltage/Current 4 Channels
IC200ALG260
Analog Input Module, 12-bit Voltage/Current 8 Channels
IC200ALG262
Analog Input Module, 15-bit Current Differential 8 Channels
IC200ALG264
Analog Input Module, 15-bit Current 15 Channels
IC200ALG266
Analog Input 15-bit Current 15Ch with enhanced over voltage protection
IC200ALG320
Analog Output Module, 12-bit Current, 4 Channels
IC200ALG321
Analog Output Module, 12-bit Voltage 4 Channels. 0 to +10Vdc Range
IC200ALG322
Analog Output Module, 12-bit Voltage 4 Channels. -10 to +10Vdc Range
IC200ALG325
Analog Output Module, 13-bit Voltage 8 Channels
IC200ALG326
Analog Output Module, 13-bit Current 8 Channels
IC200ALG327
Analog Output Module, 13-bit Voltage 12 Channels
IC200ALG328
Analog Output Module, 13-bit Current 12 Channels
IC200ALG430
Analog Mixed Module, Input Current 4 Channels, Output Current 2 Channels
IC200ALG431
Analog Mixed Module, 0 to +10Vdc Input 4 Channels, Output 0 to +10Vdc 2 Channels
IC200ALG432
Analog Mixed Module, 12-bit -10 to +10Vdc, Input 4 Channels / Output -10 to +10Vdc 2 Channels
All VersaMax Analog modules, except MDD841 and ALG331, support a default Analog value of zero only.
Before their parameters can be configured, these modules require an additional configuration step in Machine
Edition after being added to the PNS remote node.
When one of the above modules is added to the Configuration, the Navigator window shows a Configuration
Mismatch for the module (and for its PNS). This situation needs to be resolved before continuing, as described
in Section 3.7.5.2.
Figure 69 shows a configuration in which two modules have this type of mismatch:
Figure 69: Analog Modules Requiring Jumper-Setting Designation
Double-clicking one of these modules, or right-clicking and selecting Configure displays only the Power
Consumption and GSDML tabs. The Settings tab and other configuration tabs do not appear. To begin
configuring one of these modules, right-click the module in the Navigator and select Change Submodule List
from the menu.
GFK-2571N
May 2018
Chapter 3. Configuration
73