2. List of Parameters

Function
FN_
Accelerate /
Decelerate Time
Operation mode
Motor direction
V/F Pattern
Frequency
upper/lower limit
SPI frequency
JOG frequency
10
Operation control
11
Frequency Control
Carrier frequency
12
Torque compensation
13
Stop method
14
15
DC braking setting
16
17
Electronic thermal
18
19
Multifunction input
connection point
20
21
Multi-function output
22
Reverse instruction
23
Momentary power
loss
Auto restart
24
25
Factory setting
26
27
28
Software version
29
Fault trace
30
NOTE:
*1: Indicate this parameter can be adjusted during running mode
*2: Please refer to Fn_25
*3: If the setting range is above 100 , the setting unit becomes 1.
Function Description
0
Factory Adjustment
1
Accelerate time
2
Decelerate time
3
0: Forward / Stop, Reverse / Stop
1:Run/Stop, Forward / Reverse
4
0: Forward
1: Reverse
5
V/F pattern setting
6
Frequency upper limit
7
Frequency lower limit
8
SP1 frequency
9
JOG frequency
0:keypad
1: external terminal
0:keypad
1:external terminal(0~10v/0~20mA )
2: external terminal ( 4~20mA )
Carrier Frequency setting
Torque compensation gain
0:decelerate stop, 1:free run stop
DC braking time
DC braking injection frequency
DC braking level
Protection on motor rated current
Multifunction input terminal 1
function
Multifunction input terminal 2
function
Multifunction output terminal
0: REV run enabled
1: REV run disabled
0: enabled
1: disabled
Number of Auto-restart times
010: Constants initialization to 50Hz system
020: Constants initialization to 60Hz system
Reserve
Reserve
Reserve
CPU program version
Last 3 malfunction memory
Unit
0.1SEC
0.1SEC
1
1
1
0.1Hz
0.1Hz
0.1Hz
0.1Hz
1.0~ 10.0Hz
1
1
1
0.1%
1
0.1S
0.1Hz
0.1%
1%
1: Jog
2: Sp1
3: Emergency stop
4: External Base Block
5. Reset
1: Operating
2: Frequency reached
3: Fault
1
1
1
19
Range
Factory
Note
setting
0
0.1 ~ 999 S
5.0
*1*3
0.1 ~ 999 S
5.0
*1*3
0 ~ 1
0
0 ~ 1
0
*1
1 ~ 6
1/4
*2
1.0 ~ 120Hz 50/60Hz *2*3
0.0 ~ 120Hz
0.0Hz
*3
1.0 ~ 120Hz
10Hz
*3
6Hz
0 ~ 1
0
0 ~ 2
0
1 ~ 5
5
0.0 ~ 10.0%
0.0%
*1
0 ~ 1
0
0.0 ~ 25.5S
0.5S
1 ~ 10Hz
1.5Hz
0.0 ~ 20.0%
8.0%
50 ~ 100%
100%
2
5
3
0 ~ 1
0
0 ~ 1
0
0 ~ 5
0
*2