Order Information
iPC – AXXCBL800CVCR
MM – 958262
UPC – 00735858346184
EAN – 5032037106467
MOQ – 1
iPC – AXXCBL620CRCR
MM – 958263
UPC – 00735858346191
EAN – 5032037106474
MOQ – 1
iPC – A1U4PRTCXCXK
MM – 958358
UPC – 00735858346207
EAN – 5032037106481
MOQ – 1
iPC – A2U4PRTCXCXK
MM – 958264
UPC – 00735858346214
EAN – 5032037106498
MOQ – 1
iPC – A1U4PSWCXCVK
MM – 964522
UPC – 00735858366502
EAN – 5032037121002
MOQ – 1
iPC – A2U4PSWCXCXK1
MM – 958266
UPC – 00735858346221
EAN – 5032037106504
MOQ – 1
800 mm long, accessory cable kit (1 cable included), straight OCuLink SFF-8611
connector to right angle OCuLink SFF-8611 connector
Used in R1208, R2208, R2208+8, and R2224 systems to connect the server board
OCuLink SSD connector to a HSBP SSD connector
620 mm long, accessory cable kit (1 cable included), right angle OCuLink SFF-8611
connector to right angle OCuLink SFF-8611 connector
Used to connect a server board OCuLink connector SSD#2 to HSBP drive 10 of the
R2312 system SKUs
1U Retimer accessory cable kit, Riser 2 (1 cable included). Contains the following
OCuLink bundled cable:
945mm long, four straight OCuLink SFF-8611connectors to four straight OCuLink
SFF-8611 connectors
Used in the R1208 to connect AXXP3RTX16040 4-Port PCIe SSD Retimer AIC to a
PCIe SSD capable HSBP SSD ports 4-7
2U Retimer accessory cable kit, Riser 2 (1 cable included). Contains the following
OCuLink bundled cable:
815mm long, straight OCuLink SFF-8611connectors to straight OCuLink SFF-8611
connectors
Used in the R2208, R2216 and R2224 to connect AXXP3RTX16040 4-Port PCIe SSD
Retimer AIC to a PCIe SSD capable HSBP SSD ports (1 cable kit required per retimer
installed)
1U 4 port Switch accessory cable kit – 1U 4 port Switch accessory cable kit (1 cable
included). Contains the following OCuLink bundled cable:
890mm long, bundled cable kit (1 cable included) right-angle OCuLink SFF-8611
connectors to straight/right angle OCuLink SFF-8611 connectors
Used in the R1208 to connect switch AIC to HSBP PCIe SSD ports
2U 4 port Switch accessory cable kit, Riser 1 or Riser 2 (1 cable included). Contains
the following OCuLink bundled cable:
755mm long, bundled cable kit (1 cable included) straight OCuLink SFF-
8611connectors to straight/right angle OCuLink SFF-8611 connectors
Used in the R2208, R2208+8 and R2224 to connect switch AICs to HSBP PCIe SSD
ports (SSD ports depend on installed location of the switch AIC)