A. Technical appendix
A.1
Technical specifications of field bus node type CPX−FB11
General information
General technical data
Protection class as per EN 60529, CPX−FB11 fitted
completely, plug connector as per Accessories,
plugged in or fitted with protective cap.
Protection against electric shock
(Protection against direct and indirect contact as per
IEC/DIN EN 60204−1)
Current consumption of field bus node CPX−FB11
Internal current consumption at 24 V
(internal electronics):
from operating voltage supply for electronics/
sensors (V
)
EL/SEN
Electrical isolation
DeviceNet interface
Module code (CPX−specific)
Module identification (handheld)
Field bus
Protocol
Baud rate
Cable type
Cable length
(depends on baud rate and cable type)
Festo P.BE−CPX−FB11−EN en 0503b
See CPX system manual P.BE−CPX−SYS−...
IP65/IP67
By means of PELV power circuit
(Protective Extra−Low Voltage)
Typ. 65 mA
Electrically isolated (optocoupler)
Remote I/O:
Remote Controller:
Remote I/O:
FB11−RIO DeviceNet Remote I/O
Remote Controller:
FB11−RC DeviceNet bus node
DeviceNet according to ODVA specification V 2.0
125 kBaud, 250 kBaud, 500 kBaud
See DeviceNet specification part 1, appendix B and
installation guidelines for your controller
Max. 500 m
204
155
A−3