Object
Instances
classes
(dez.)
4
101 ... 103
d
115
1
d
114
1
d
102
1 ... 32
d
120
1 ... 32
d
104
1 ... 32
d
125
1 ... 32
d
126
1 ... 32
d
127
1 ... 32
d
116
1 ... 40
d
117
1
d
Tab. 2/20: Object classes for modular EDS (overview)
Festo P.BE−CPX−FB11−EN en 0503b
In order to address the CPX terminal with modular EDS, you
will require the following object descriptions:
Attributes
Name
(dez.)
Assembly object instances
100 ... 102
Status and diagnostic object
1 ... 37
Module−independent system object
99 ... 134
Parameter Object Module
1 ... 188
General object module parameters
100 ... 172
Modification of digital inputs, object
100 ... 172
Modification of digital outputs, object
100 ... 172
Modification of analogue outputs, object
100 ... 172
Modification of analogue inputs, object
1 ... 12
Diagnosis of trace object
1 ... 13
Diagnosis of trace status object
Detailed object descriptions for modular EDS can be found in
appendix C.1.
Type
(various)
(various)
USINT/BYTE
(various)
(various)
WORD
WORD
(various)
(various)
USINT/BYTE
(various)
2−55