B. DeviceNet objects with Standard EDS
Attr. no.
Access
110
Get/Set
111
112
113
Get/Set
114
Get/Set
115
...
118
119
Get/Set
...
...
150
Get/Set
151
Get/Set
...
...
166
Get/Set
167
Get/Set
...
...
174
Get/Set
Festo P.BE−CPX−FB11−EN en 0503b
Description
Signal extension time (value range 0 ... 3)
0: 0.5 ms
1: 15 ms (typical presetting)
2: 50 ms
3: 100 ms
Reserved
Reserved
Data format analogue value inputs
Data format analogue value outputs
Reserved
1. Byte parameter of the module
...
32. Byte parameter of the module
1. Word parameter of the module
...
16. Word parameter of the module
1. Double word parameter
...
8. Double word parameter
Type
Function no.
USINT
4828 + m * 64 + 1
(bits 6, 7)
USINT
4828 + m * 64 + 3
(bits 0, 1)
USINT
4828 + m * 64 + 3
(bits 4, 5)
SINT
...
SINT
INT
...
INT
DINT
...
DINT
B−9