Appendix A. Product Specifications
Pressure Transducer Ranges
Full Scale Operating Pressure
1
To maximize accuracy, specify the lowest full scale operating pressure range for
the application. To avoid damage, the flowmeter must never be subjected to
pressure above the over-range pressure shown above.
Power Requirements
12 to 36 VDC, 25 mA, 1 W max., Loop Powered Volumetric or Mass
12 to 36 VDC, 300 mA, 9 W max. Multiparameter Mass options
100 to 240 VAC, 50/60 Hz, 5 W max. Multiparameter Mass options
Class I Equipment (Grounded Type)
Installation (Over-voltage) Category II for transient over-voltages
AC & DC Mains supply voltage fluctuations are not to exceed ±10% of the rated supply voltage range.
User is responsible for the provision of an external Disconnect Means (and Over-Current Protection)
for the equipment (both AC and DC models).
Display
Alphanumeric 2 x 16 LCD digital display:
Six push-button switches (UP, DOWN, RIGHT, LEFT, ENTER, EXIT) operable through explosion-proof window using
hand-held magnet. Viewing at 90-degree mounting intervals.
130
Pressure Sensor Ranges
psia
bara
30
100
300
20
500
35
1500
100
1
, psia (bara)
Maximum Over-Range Pressure
psia
2
60
7
200
600
1000
2500
bara
4
14
40
70
175
PanaFlow™ MV80 & MV82 User's Manual