Flow Rates (cont.)
Pressure
15
0 barg
3
28
5 barg
7
165
10 barg
9
304
15 barg
11
442
20 barg
13
582
30 barg
16
862
Linear Range
Smart electronics corrects for lower flow down to a Reynolds number of 5,000. The Reynolds number is calculated
using the fluid's actual temperature and pressure monitored by the meter. Rangeability depends on the fluid, process
connections and pipe size. Consult factory for your application. Typical velocity range ability in standard applications
is as follows:
Liquids 30:1
1 foot per second velocity minimum
30 feet per second velocity maximum
Gases 30:1
10 feet per second velocity minimum
300 feet per second velocity maximum
PanaFlow™ MV80 & MV82 User's Manual
Typical Air (@20°F) Minimum and Maximum Flow Rates (nm
20
25
5
9
66
142
13
21
390
847
17
29
716
1554
21
34
1044
2265
24
40
1373
2979
29
48
2034
4414
Nominal Pipe Size (mm)
40
50
21
36
350
584
52
87
2080
3476
70
117
3819
6381
14273
85
142
5565
9299
20801
97
162
7318
12229
27354
118
198
10843
18119
40529
Appendix A. Product Specifications
3
/hr)
80
100
79
138
1307
2275
5157
194
337
7775
13533
30682
262
457
1035
24844
56329
317
551
1250
36205
82087
363
632
1434
47612
107949
442
770
1745
70544
159942
150
200
313
549
9034
764
1339
53749
1814
98676
2190
143801
2511
189105
3057
280187
127
Need help?
Do you have a question about the PanaFlow MV80 and is the answer not in the manual?