Aes67 Page - AMX N2412A Instruction Manual

N2400 series. encoder/decoder digital media distribution & switching solution
Table of Contents

Advertisement

TABLE 17
Command
Port
Device Number
System Number
Username
Password
Save button

AES67 Page

Click the AES67 link at the top of any of the main web pages to access the page shown in
Table
18. AES67 is an open standard for audio over IP and audio over Ethernet. This page allows you to configure the Encoder to
generate AES67 audio and send it to devices that support it.
AES67 Page
FIG. 39
TABLE 18
Command
AES67 Audio
AES67 Audio Address
AES67 Audio Port
Save button
N2412A/N2422A User Manual
NetLinx Page Options (Cont.)
Description
This field should always be set to 1319.
Defaults to a dynamic device number. May be set to a static range (e.g., 8000).
Determines which system to connect. This setting is dependent upon the Master Mode selected (see above).
• If Master Mode is set to Auto, the System Number is set and the system discovers the Master Controller's IP
address.
• If Master Mode is set to Listen, the device connects to any Master Controller.
• If Master Mode is set to URL, the IP of the Master Controller is set.
Username for the Master Controller.
Password for the Master Controller.
Click to save settings made on this page.
AES67 Page Options
Description
Enable to turn on AES67 audio and turn off other audio streams.
Enter the IP address of the destination device. The address's first octet must start with 239 (e.g.,
239.xxx.xxx.xxx). It will not work with other numbers for the first octet.
Enter the port number of the destination device.
Click to save settings made on this page.
Encoder Configuration Options