NOTE: If the LocalPlay screen does not appear, refer to the chapter Troubleshooting on page 67 for more guidance.
NOTE: In order for the unit to receive PoE+, it must be connected to a switch or other equipment that has a PoE+ PSE (Power
Sourcing Equipment) port. PoE+ does not pass through the daisy chain (P1) port.
CAUTION:
Do not run wiring that is connected to a PoE+ PSE port outside of the building where the PSE resides. It is for intra-building
use only.
Step 3: Connecting Encoders to the Network and Configuring Stream
Settings
1.
Using a Cat-5 cable, connect your N-Series Encoder's P0 port to a PoE+ enabled switch. In non-PoE applications connect a
12V regulated power supply (FGN9313) to the two-pin terminal block plug connector (labeled +12V 3A).
NOTE: In order for the unit to receive PoE+, it must be connected to a switch or other equipment that has a PoE+ PSE port.
2.
In N-Able, select the Unit Management tab and click the Auto Discover button (if the table has not already populated itself
with the installed units). See
Unit Management Page
FIG. 10
3.
Find your Encoder in the list. N2400 units are displayed on the following tabs:
• Unit Management tab — N2400 units have N2400 Encoder/Decoder listed in their Type fields.
• Video Matrix tab — N2400 units are found on the N2400 sub-tab (as shown in
NOTE: If using multiple Encoders in your set up, it is important to plug in and configure one Encoder at a time. As you add Encoders
to the network, you will need to set them up to use different streams.
N2412A/N2422A User Manual
Figure
10.
Installing and Configuring Your AV Equipment
Figure
11).
15