Mitsubishi Electric FX5-DP-M User Manual page 59

Melsec iq-f series
Table of Contents

Advertisement

Set Slave Address
Changes the FDL address of the DP-Slaves with Online.
Item
Description
Old address
Sets the current DP-Slave number.
When the DP-Slave is selected in a project tree, the FDL address of DP-Slave is displayed.
When the DP-Master is selected in a project tree, input an arbitrary effective FDL address.
New
Sets a new DP-Slave number.
address
Ident-No.
Sets the Ident No. of the DP-Slave of which FDL address is to be changed.
When the DP-Slave is selected in a project tree, the Ident No. of the selected DP-Slave is displayed.
When the DP-Master is selected in a project tree, set the Ident No. in hexadecimal.
Messages
Displays the new FDL address when the [Set] button is clicked.
Below are examples of displayed messages.
• FDL address change request has been sent: A request to change the FDL address was sent.
• Failed to change FDL address: The system failed to change the FDL address.
• For setting the slave address the data exchange on the PROFIBUS network must be stopped!: The FDL address cannot be
changed during data exchange.
Precautions
"FDL address change request has been sent" in "Messages" indicates only a request to change the FDL address was sent
successfully.
• Check that the FDL address has changed.
• The FDL address of DP-Slave can change only if the DP-Slave is supported by changing it from DP-Master. (Refer to the
manual for the DP-Slave)
8 PROFIBUS Configuration Tool
8.2 "PROFIBUS Configurator Tasks" Window
Setting
range
0 to 126
0 to 125
0H to
FFFFH
8
57