Ignition phase of the burner

The adjusted start dose is given to
the combustion chamber.The ignitor
is lit for 30 seconds. The fan ramps
in three cycles.
If the flame sensor detects lights
the burner goes to operation
mode in seq 1.
22
Effecta AB Västra Rågdalsvägen 21 434 99 Kungsbacka Sweden +46-300 - 22320 info@effecta.se
Function test of the flame sensor. Must be illuminated to test function.
Activates ignitor, the fan starts at 40% to protect the ignitor.
Activates the auger/feeder.
Activates the fan
Activates compressor for cleaning.
Activates/opens solenoid valve for cleaning.
Activates and tests the full AERO cleaning cycle.
Activates the flue cleaning.
Activates the shunt motors open or close, +/-
Activates electrical heater.
Activates the radiator pump.
Activates the loading pump for another unit such as Laddomat.
Activates and tests flue gas fan
Amount of failed ignitions
Amount of Start phase failure
Amount of Operation phase failure
There has been a problem during operation phase. Most likely
problem is that the pellets hvae run out. Flame sensor can also
be covered by soot.
The burner has missed the ignition phase, most likely problem
is poorly adjusted starting dose. Also check the ignitor in the
function test.
The flue gas temperature has been above 320°C. This is a extr-
mely high temperature, please check that the automatic cleaning
is working (function test). Also check the flue gas sensor.
The temperature of the boiler has been above its max value.
Normally this can happen from the heat after the combustion
cycle. Try to lower the stopping temeprature if the problem reoc-
curs.
The burner fan has stopped when it should be running. Check
for faults on the fan.
If the flame sensors doesn´t detect
a flame the burner gives a support
dose. The fan ramps up in three
cycles.
If the flame sensor detects
lights the burner goes to opera-
tion mode in seq 2.
If the flame sensors still doesn´t
detect a flame the burner gives a
support dose. The fan ramps up in
three cycles.
If the flame sensor detects lights
the burner goes to operation mode
in seq 3.
If there is no light in seq 3 "ALARM
START" will be shown in display.