4.7

Inter-module Synchronization Function

This function adjusts the input or output timing of modules to be synchronized to the inter-module synchronization cycle by
matching the control timing of signals among multiple modules.
Program
C Controller module
Inter-module synchronous
interrupt program (I44)
A/D converter module
(set as a synchronization target)
D/A converter module
(set as a synchronization target)
Input module
(set as a synchronization target)
Output module
(set as a synchronization target)
For details on the inter module synchronization function, refer to the following manual.
MELSEC iQ-R Inter-Module Synchronization Function Reference Manual
4 BASIC FUNCTIONS
50
4.7 Inter-module Synchronization Function
Input module
C Controller module
Inter-module synchronization cycle
Operation processing
Output
Input
conversion
Output
Input
Output
Output module
A/D converter module
D/A converter module
Inter-module synchronization cycle
Operation processing
Output
Input
conversion
Output
Input
Output
Operation processing
Input
Output
Input
Output