Mitsubishi Electric MELSEC iQ-R C R12CCPU-V User Manual page 214

Controller module
Hide thumbs Also See for MELSEC iQ-R C R12CCPU-V:
Table of Contents

Advertisement

System information
The special relays for system information are as follows.
No.
Name
*1
SM220
CPU No.1 preparation
completed
*1
SM221
CPU No.2 preparation
completed
*1
SM222
CPU No.3 preparation
completed
*1
SM223
CPU No.4 preparation
completed
*1 These devices are used as an interlock to access the CPU No.1 when the multiple CPU synchronization setting is configured with
asynchronous mode.
Firmware update function
The special relays for the firmware update function are as follows.
No.
Name
SM922
Firmware update
completion with/without an
error
CC-Link IE Field Network Basic function
The special relays related to the CC-Link IE Field Network Basic function are as follows.
No.
Name
SM1536
Cyclic transmission status
SM1540
Data link status
APPX
212
Appendix 5 Special Relay List
Content
Details
OFF: CPU No.1
This device turns ON when the access from another CPU
preparation not
module to the CPU No.1 is enabled after turning the
completed
power ON or resetting the module.
ON: CPU No.1
preparation completed
OFF: CPU No.2
This device turns ON when the access from another CPU
preparation not
module to the CPU No.2 is enabled after turning the
completed
power ON or resetting the module.
ON: CPU No.2
preparation completed
OFF: CPU No.3
This device turns ON when the access from another CPU
preparation not
module to the CPU No.3 is enabled after turning the
completed
power ON or resetting the module.
ON: CPU No.3
preparation completed
OFF: CPU No.4
This device turns ON when the access from another CPU
preparation not
module to the CPU No.4 is enabled after turning the
completed
power ON or resetting the module.
ON: CPU No.4
preparation completed
Content
Details
OFF: Update completed
This device turns ON when the firmware update function
without an error (including
is completed with an error. (SM922 turns ON when 'Latest
successful completion)
firmware update result' (SD922) is in the range from
ON: Update completed
'100H' to '300H'.)
with an error
Content
Details
OFF: Transmission not
This device turns ON when cyclic transmission is started,
executed
and turns OFF when the cyclic transmission is stopped.
ON: Transmitting
OFF: No error station
This device turns ON when an error occurs in one or more
ON: Error station found
slave stations.
The status of each slave station can be checked with
'Data link status of each station' (SD1540).
Set by (when to set)
S (status change)
S (status change)
S (status change)
S (status change)
Set by (when to set)
S (initial)
Set by (when to set)
S (END processing)
S (END processing)