8.3 ISOLATED PROGRAMMING & MONITORING CONNECTOR
Refer to Table 8-1 for detailed description of the rear panel Isolated Programming & Monitoring
connector. To provide the lowest noise performance, it is recommended to use shielded-twisted
pair wiring.
Refer to Fig.8-1 for description of the connector.
Isolated programming plug P/N: MC1.5/8-ST-3.81, Phoenix.
Shield
+VPROG_ISO
+IPROG_ISO
GND
Fig.8-1: Isolated Programming & Monitoring connector
Table 8-1: Detailed description of Isolated programming & Monitoring connector
Terminal
Signal name
1
SHLD
2
+VPROG_ISO
3
+IPROG_ISO
4
GND
5
GND
6
+VMON_ISO
7
+IMON_ISO
8
SHLD
CAUTION
When the Isolated Analog Option is installed, do not
apply any signals to the non-isolated VPGM and IPGM
(J1-9 and J1-10) pins. All other J1 features may be used
normally. Refer to Section 4.5 for a description of J1
features.
Parallel Operation: Optional Isolated Analog
IS510 / IS420 must be installed in both the Master
and Slave unit.
1
2
3
5
4
Function
Shield, connected internally to
chassis of the supply.
Output voltage programming input
Output current programming input
Ground for programming
signals.
Ground for programming
signals.
Output voltage monitoring output
Output current monitoring output
Shield, connected internally to
chassis of the supply.
64
64
6
7
8
Shield
+IMON_ISO
+VMON_ISO
GND
Range 0-5/0-10V
IS510 option
Chassis ground
0-5/0-10V
0-5/0-10V
Ground
Ground
0-5/0-10V
0-5/0-10V
VORSICHT
Wenn die optionale Ansteuerung mit isolierten
Analogsignalen verwendet wird, legen Sie keinerlei
Signale an die nicht isolierten Pins VPGM oder lPGM
(J1-9 und J1-10) der Standardschnittstelle J1. Alle
übrigen J1-Funktionen können normal verwendet
werden.
Siehe Abschnitt 4.5 für eine Beschreibung der J1-
Funktionen.
Range 4-20mA
IS420 option
4-20mA
4-20mA
Ground
Ground
4-20mA
4-20mA
Chassis ground