c. Install I/O boat 1 in the same manner.
8. Lower the cable plate from the service position to the normal position
(
FIGURE 4-4
9. Attach the I/O cables to the PCI cards.
10. For each I/O boat, attach the link cable(s) to the link card in the boat.
For an optical link card, there are two connections. Insert the TX cable into the link
card port marked "TX" and insert the RX cable into the port marked "RX".
For a copper link card, there is a single connection.
11. Connect AC cords to the internal AC cables on the External I/O Expansion Unit.
12. Turn on the AC switches on the External I/O Expansion Unit PSUs.
On the PSUs the AC power (
For other LED indications, see
13. Add the PCI card to an Oracle Solaris domain.
# cfgadm -c configure ap_id
For details, refer to the service manual for your host server.
4.13

Powering Up a Link After Service

4.13.1

The cfgadm -c configure Command

After repairing a link, power up the link by typing:
# cfgadm -c configure ap_id
Where ap_id is the IOU slot in the host server to which the I/O boat is connected.